港股代码:2188 | 简 体 | 繁 体 | English
TPCS Bidirectional converter system- Europe Version

Product application

Power Conversion System (PCS) is a device to achieve energy bidirectional conversion between the battery system and the power grid (and/or load) with a variety of uses such as with peak and valley adjusting, frequency modulation, phase modulation, emergency backup, etc. It can control the charging and discharging process of the battery and convert AC and DC energy. When power grid is not connected, it can directly supply AC loads.

 

Product composition and characteristics

PCS is mainly composed of IGBTs, soft starter, isolation transformer, protection devices, and controller. The PCS controller receives background control instructions via communication and controls the converter according to the sign and value of the power instruction to charge or discharge the battery. The adjustment of the active power and reactive power of the power grid can be realized. Meanwhile, PCS can obtain battery group status information through CAN interface communication with BMS, dry contact transmission, etc., which can protect charging and discharging of the battery and ensure battery operation safety.


Technical specifications

DC side

Model

TPCS series

Voltage range (Vdc)

600~800

Rated power (kVA)

100, 250, 500

Charge/discharge voltage accuracy

≤0.5%

Charge/discharge current accuracy

≤1.0%

Ripple factor

≤0.5%

 

AC side

AC phase number

Three-phase five wire system (R+S+T+N+PE)

Rated power (kVA)

100, 250, 500

Grid-connected charging/discharging

AC voltage (Vac)

380±15%

Allowable frequency range (Hz)

50±1

Total current harmonic distortion rate

<±3% (more than half load)

Charging power factor

≥0.99 (more than half load)

Discharging output power factor

-1.0~1.0

Off grid operation

AC voltage (Vac)

380±15%

Output voltage distortion

<±3% (Rated linear load)

Rated output frequency (Hz)

50±2%

Dynamic load voltage transient

Within 10% (resistive load 0-100% step change)

AC overload capacity

110%, overload for 10 mins; 120%, overload for 1 mins

Efficiency

≥92% (more than half load,including transformer)

Function

Anti-island effect detection

Active and passive island detection

Display

Colorful touch screen

Communication mode

RS485/CAN / Ethernet interface

General paramet-ers

Cooling method

Air cooling

Noise

≤ 65dB

Protection level

IP30

Installation environment

Indoor

Safety indicators

Meet national or industry standards

版权所有:珠海八方体育(北京)有限公司科技股份有限公司 2012版权所有  粤ICP备10036002号


公众号 公众号